Section 1 · User commands
cxl-set-alert-config.1
Package: cxl-cli
On this page
CXL−SET−ALERT−CONFIG
NAME
SYNOPSIS
DESCRIPTION
EXAMPLES
OPTIONS
SEE ALSO
NAME
cxl-set-alert-config − set the warning alert threshold on a CXL memdev
SYNOPSIS
cxl set−alert−config <mem0> [<mem1>..<memN>] [<options>]
DESCRIPTION
CXL device raises an alert when its health status is changed. Critical alert shall automatically be configured by the device after a device reset. If supported, programmable warning thresholds also be initialized to vendor recommended defaults, then could be configured by the user.
Use this command to configure warning alert thresholds of a device. Having issued this command, the newly requested warning thresholds would override the previously programmed warning thresholds.
To enable warning alert, set both threshold=value and alert=on. To disable warning alert, set only alert=off. Other cases would cause errors.
Use “cxl list −m <memdev> −A” to examine the programming warning threshold capabilities of a device.
EXAMPLES
Set warning threshold to 30 and enable alert for life used.
cxl set−alert−config mem0 −−life−used−threshold=30 −−life−used−alert=on
{
“memdev”:“mem0”,
“ram_size”:“1024.00 MiB (1073.74 MB)”,
“alert_config”:{
“life_used_prog_warn_threshold_valid”:true,
“dev_over_temperature_prog_warn_threshold_valid”:false,
“dev_under_temperature_prog_warn_threshold_valid”:false,
“corrected_volatile_mem_err_prog_warn_threshold_valid”:false,
“corrected_pmem_err_prog_warn_threshold_valid”:false,
“life_used_prog_warn_threshold_writable”:true,
“dev_over_temperature_prog_warn_threshold_writable”:true,
“dev_under_temperature_prog_warn_threshold_writable”:true,
“corrected_volatile_mem_err_prog_warn_threshold_writable”:true,
“corrected_pmem_err_prog_warn_threshold_writable”:true,
“life_used_crit_alert_threshold”:75,
“life_used_prog_warn_threshold”:30,
“dev_over_temperature_crit_alert_threshold”:0,
“dev_under_temperature_crit_alert_threshold”:0,
“dev_over_temperature_prog_warn_threshold”:0,
“dev_under_temperature_prog_warn_threshold”:0,
“corrected_volatile_mem_err_prog_warn_threshold”:0,
“corrected_pmem_err_prog_warn_threshold”:0
},
“serial”:“0”,
“host”:“0000:0d:00.0”
}
cxl memdev: cmd_set_alert_config: set alert configuration 1 mem
Disable warning alert for life_used.
cxl set−alert−config mem0 −−life−used−alert=off
{
“memdev”:“mem0”,
“ram_size”:“1024.00 MiB (1073.74 MB)”,
“alert_config”:{
“life_used_prog_warn_threshold_valid”:false,
“dev_over_temperature_prog_warn_threshold_valid”:false,
“dev_under_temperature_prog_warn_threshold_valid”:false,
“corrected_volatile_mem_err_prog_warn_threshold_valid”:false,
“corrected_pmem_err_prog_warn_threshold_valid”:false,
“life_used_prog_warn_threshold_writable”:true,
“dev_over_temperature_prog_warn_threshold_writable”:true,
“dev_under_temperature_prog_warn_threshold_writable”:true,
“corrected_volatile_mem_err_prog_warn_threshold_writable”:true,
“corrected_pmem_err_prog_warn_threshold_writable”:true,
“life_used_crit_alert_threshold”:75,
“life_used_prog_warn_threshold”:30,
“dev_over_temperature_crit_alert_threshold”:0,
“dev_under_temperature_crit_alert_threshold”:0,
“dev_over_temperature_prog_warn_threshold”:0,
“dev_under_temperature_prog_warn_threshold”:0,
“corrected_volatile_mem_err_prog_warn_threshold”:0,
“corrected_pmem_err_prog_warn_threshold”:0
},
“serial”:“0”,
“host”:“0000:0d:00.0”
}
cxl memdev: cmd_set_alert_config: set alert configuration 1 mem
OPTIONS
<memory device(s)>
A memX device name, or a memdev id number. Restrict the operation to the specified memdev(s). The keyword all can be specified to indicate the lack of any restriction.
−S, −−serial
Rather an a memdev id number, interpret the <memdev> argument(s) as a list of serial numbers.
−L, −−life−used−threshold=
Set <value> for the life used warning alert threshold.
−−life−used−alert=
Enable or disable the life used warning alert. Options are on or off.
−O, −−over−temperature−threshold=
Set <value> for the device over temperature warning alert threshold.
−−over−temperature−alert=
Enable or disable the device over temperature warning alert. Options are on or off.
−U, −−under−temperature−threshold=
Set <value> for the device under temperature warning alert threshold.
−−under−temperature−alert=
Enable or disable the device under temperature warning alert. Options are on or off.
−V, −−volatile−mem−err−threshold=
Set <value> for the corrected volatile memory error warning alert threshold.
−−volatile−mem−err−alert=
Enable or disable the corrected volatile memory error warning alert. Options are on or off.
−P, −−pmem−err−threshold=
Set <value> for the corrected persistent memory error warning alert threshold.
−−pmem−err−alert=
Enable or disable the corrected persistent memory error warning alert. Options are on or off.
−v, −−verbose
Turn on verbose debug messages in the library (if libcxl was built with logging and debug enabled).
SEE ALSO
CXL−3.0 8.2.9.8.3.3