Section 1 · User commands
nvme-zns-open-zone.1
Package: nvme-cli
On this page
NVME−ZNS−OPEN−ZON
NAME
SYNOPSIS
DESCRIPTION
OPTIONS
EXAMPLES
NVME
NAME
nvme-zns-open-zone − Opens one or all zones
SYNOPSIS
nvme zns open−zone <device> [−−namespace−id=<NUM> | −n <NUM>]
[−−start−lba=<LBA> | −s <LBA>] [−−zrwaa | −r]
[−−select−all | −a] [−−timeout=<timeout> | −t <timeout>]
DESCRIPTION
For the NVMe device given, issues the Zone Management Send command with the “Open Zone” action. This will transition the zone to the opened state.
The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).
OPTIONS
−n <NUM>, −−namespace−id=<NUM>
Use the provided namespace id for the command. If not provided, the namespace id of the block device will be used. If the command is issued to a non−block device, the parameter is required.
−s <lba>, −−start−lba=<lba>
The starting LBA of the zone to open.
−r, −−zrwaa
Allocate Zone Random Write Area to zone
−a, −−select−all
Select all zones for this action
−t <timeout>, −−timeout=<timeout>
Override default timeout value. In milliseconds.
EXAMPLES
• Open the first zone on namespace 1:
nvme zns open−zone /dev/nvme0 −n 1 −s 0
NVME
Part of nvme−cli